A Monitoring System Solution for One ICBC Subdivision
Keywords: monitoring, monitoring system, monitoring solution, video monitoring
1. System Brief Introduction
Current science develops fast and the whole society has been entering digitalization, information age. Accordingly, monitoring work has been showed much attention among people. But using high & new skill to prevent, stop, hit criminal has been more and more important in three main methods (human defend, prevent defend and technical defend). More enterprises aim to create newer monitoring products and better monitoring solutions.
Bank belongs to the vital safeguarding department. Monitoring work must do the best. Just for the diverse scales, numerous facilities and various people, wide management features, bank has been the key sector of monetary transaction and economic operation. Bank widely serves various fields in China, so it becomes particularly important to enhance scientific management & security prevention in bank system.
According to the “security engineering process and requirement (GA/T75-94)” of the MPS (The Ministry of Public Security of the People’s Republic of China) and the related regulations of security prevention of Beijing Public Security Bureau, all CCTV industry staff should comply with the below principles: engineering safety & reliability; product reliability & compatibility; system expansion ability; centralized control & reasonable layout; convenient engineering, proper price, beautiful shape; meet requirement of security prevention of the MPS. Meantime, based on experience of bank of xxx security management, design and setup top class security system.
2. System Form & Function
a. System form
This monitoring system consists of CCTV monitoring sector and alarm sector.
CCTV monitoring system includes front-end equipments, transmission devices and main control equipments, displaying equipments. The front-end equipments are composed by scattered cameras, lenses, housings and pan/tilts, which is responsible for picture data capturing & signal process; Transmission equipments include coaxial cable and signal cable, which are in charge of transmitting audio & video signal to main control equipments; Main control equipments are responsible for controlling front-end audio & video signal with compression, picture switch and PTZ operation; Displaying equipments mainly refer to monitors which display system window, monitoring area image as well as playback & save data.
Alarm system comprises alarm sensor, transmission devices, alarm controller and communication sector. Alarm sensor is placed on spot to detect targets; alarm controller processes alarm signal from front-end sensor; communication sector mainly connects to alarm center with wires.
Traditional control mode (analog mode) is scattered, in which monitoring and alarm are separately operated and controlled, hard to be managed by person. Nowadays, we adopt advanced multimedia PC monitoring concept forming a new type control platform (DVR) by digital monitoring server, on which all subdivision functions are centralized. We just press mouse and can easily manage them, thus it makes management easier, more visible, more convenient as well as more cost-saving.
b. System functions
Guarding persons with multimedia server can control front-end equipments, like camera, pan/tilt, invading detector, etc, so as to fully control, real-time monitor and precisely record the key spots of bank as well as important passages or entrance. In addition to that we can use linkage devices to realize invading alarm at night, linkage shining and auto record.
In all spots, cameras can monitor the activities and managers can instantly learn the situation details there, even the spot activities can be recorded in order to be checked later. Manager can use keyboard to call any camera images onto main monitor, controlling camera rotation and zooming the image to get optimum effect.
By making alarm on/off for ambient security, we can greatly prevent burglar from invading. We also use linkage function to automatically open light and display alarm position & images on monitor, by this way to display & record image. Moreover with auto record we can easily get high definition effect.
Besides, main control system can be managed with different levels. In the help of LAN network in building, main manager can use sub-controller to obtain inner-building activities at anytime, even make management in order to realize macro and micro management.
3. System Environment Demand
After practical examine about spot, we know that system equipments designment, producing, test and debug can operate long-term in Northern China environment -19℃---37℃ and relative humidity 95%, as statistics of China Meteorological Administration.
4. System Specifications Standard
Device mean time between failures (MTBF) not less than 20000 hours
PC Mean Time Between Failures (MTBF) not less than 20000 hours
Monitor complies with UL authentication and A-class limitation of FCC standard
Camera complies with UL1409 safety standard and A-class radiation of FCC standard
Detector complies with UL authentication and the MPS’s test
Composite video signal amplitude: lvp-p±3dB
Color TV-set horizontal resolution: >380 TVL
S/N ratio: ≥37dB
Grayscale: 8 grades
This monitoring solution belongs to Beijing Backbone Computer Technology Co., Ltd. If want to copy, please label owner. Beijing Backbone Computer Technology Co., Ltd provides various video monitoring equipments and remote video monitoring system solutions. We have already set up series products of video monitoring equipment based on IDRS and Bernee brands.